EasyManuals Logo

Siemens SINUMERIK 804D sl Function Manual

Siemens SINUMERIK 804D sl
2050 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1454 background imageLoading...
Page #1454 background image
Detailed Description
2.4 Referencing with incremental measurement systems
Reference Point Approach (R1)
2-14 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
7KHUPDOH[SDQVLRQ
&DPVLJQDO
=HURPDUNVHDUFK
=HURPDUN
&DPVLJQDOZLWK
RIIVHW
0'0$B5()3B&$0B6+,)7

Fig. 2-7 Electronic reference cam offset
Reference cam adjustment
Encoder with equidistant zero marks
Always ensure that the reference cam of encoders that supply zero marks at equidistances
is accurately adjusted so that the correct zero mark is always detected during reference point
approach.
Dynamic response
The following factors will influence the dynamic response between arrival at the reference
cam on the machine and detection of the reference cam signal transmitted from the PLC
user program to the NC:
Switching accuracy of the reference cam switch
Delay of the reference cam switch (NC contact)
Delay at the PLC input
PLC cycle time
Cycle time for updating the VDI interface
Interpolation cycle
Position control cycle

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals