Detailed Description
2.6 Block search Type 5 SERUPRO
Mode Group, Channel, Program Operation, Reset Response (K1)
2-52 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Interface signal:
DB31, ... DBX70.2 (Repos Delay Ackn)
is defined in the same way.
DB31, ... DBX70.1 (Repos offset valid) =1
if:
DB21, ... DBX319.1-319.3 (Repos Path Mode Ackn0 to 2) = 4 (RMN).
Valid REPOS offset
When the SERUPRO operation is complete, the user can read out the REPOS offset via the
axis/spindle VDI signal (NCK→PLC):
DB31, ... DBX70.0 (REPOS offset).
The effects of this signal on the relevant axis are as follows:
Value 0: No REPOS offset is applied.
Value 1: REPOS offset is applied.
Range of validity
Interface signal:
DB31, ... DBX70.0 (REPOS offset)
is supplied at the end of the SERUPRO operation.
The REPOS offset is invalidated at the start of a SERUPRO ASUB or the automatic ASUB
start.
Updating the REPOS offset within the scope
Between the SERUPRO end and SERUPRO start, the axis can be moved in JOG mode with
a mode change.
In JOG mode, the user manually moves the axis over the REPOS offset path
in order to set interface signal:
DB31, ... DBX70.0 (REPOS offset)
to the value 0.
Within the range of validity, the axis can also be traversed using FC18, whereby DB31, ...
DBX70.0 is continuously updated.

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals