File and Program Management
3.3 Defining user data
Job planning
3-8 Programming Manual, 03/2006 Edition, 6FC5398-2BP10-1BA0
Loading initialization programs
INI programs can also be selected and called as parts programs if they only use the data of
a single channel. It is thus also possible to initialize program-controlled data.
Information on file types is given in the Operator's Guide.
3.3 3.3 Defining user data
Function
Notice
User data (GUD) is defined at the time of start-up. The necessary machine data should be
initialized accordingly. The user memory must be configured. All relevant machine data have
as a component of their name GUD.
The user data definition (GUD) can be prepared in the Services operating area of the HMI
user interface. This eliminates the time-consuming reimport from data backup
(%_N_INITIAL_INI).
The following applies:
• Definition files that are on the hard disk are not active.
• Definition files that are on the NC are always active.
Programming
The GUD variables are programmed with the DEF command:
DEF range preprocessing stop type name[.., ...]=value

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals