11.90 4 Monitoring Functions
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
3021
”CRC/TNRC contour error”
Reason:
Remedy:
The compensation calculation results in a traversing movement which
is in the opposite direction to the movement programmed.
Check the program.
Alarm No.
Alarm Text:
3024
”Display description not available”
Reason:
Remedy:
Explanation:
A jump has been made with a programmed softkey to a display which
is not present in the UMS memory.
– check graphic display number
– check softkey function
Only with additional programming developed in WS800.
Alarm No.
Alarm Text:
3025
”Display description error”
Reason:
Remedy:
Explanation:
– A display with graphic elements has been programmed, without the
graphic option fitted in the control
– The selected display has too many variables or fields
– A type of display has been programmed that is not valid for the
control
– Check the display using the workstation
– Retrofit graphics option
Only with additional programming developed in WS800
Alarm No.
Alarm Text:
3026
”Graphics / text too voluminous”
Reason:
Remedy:
Explanation:
– Projecting error in selected display
– Sum of the display and text elements too large
– Check the display using the workstation
– Distribute the contents over two displays
Only with additional programming developed in WS800
Alarm No.
Alarm Text:
3027
”Too many graphics commands”
Reason:
Remedy:
Explanation:
The total of graphics commands in the display selected is too great
As for alarm 3026
– This alarm triggers alarm 3026
– Only with additional programming via WS800
Alarm No.
Alarm Text:
3028
”Too many field/variables”
Remarks: Alarm only on commissioning
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EQ02 4-29
SINUMERIK 810M, GA3 (BN)