4 Monitoring Functions 09.91
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
3013
”Simulation disabled”
Reason:
Remedy:
When the appropriate machine data is set, graphic simulation (for
testing part programs) is only possible when a program is not being
simultaneously run on the machine.
Alarm No.
Alarm Text:
3016
”External data input error”
Reason:
Effect:
Remedy:
During external data input from PLC to NC:
the code is incorrect
the value is too large
the dimension identifier is invalid
the option is not fitted
Data transfer is interrupted
Check PLC program
or call Service
Alarm No.
Alarm Text:
3017
”Part prog. no. occurs twice”
Reason:
Effect:
Remedy:
There is a program present on the Cycles EPROM submodule, which
is also present in the part program (RAM) memory.
Inhibiting of NC START
Delete the program in RAM
Alarm No.
Alarm Text:
3018
”Distance from contour too great (NC MD9)”
Reason:
Effect:
Remedy:
After re-positioning to a circular contour, the distance between the
axes and the contour is too great.
The NC inhibits ”Program Start”.
Re-traverse to the contour to reduce the distance.
Alarm No.
Alarm Text:
3019
”Option RS232 not available”
Reason:
Effect:
Remedy:
The 2nd RS232C (V.24) interface has been started, either from the
PLC or with the softkey, but the option is not fitted.
Transfer data via the 1st RS232C (V.24) interface.
Retrofit option C62 (2nd RS232C (V.24) interface)
Alarm No.
Alarm Text:
3020
”Option not available”
Reason:
Remedy:
A function has been programmed which is not implemented in the
system.
As for alarm 3000
Retrofit option
4-28
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EQ02
SINUMERIK 810M, GA3 (BN)