Note
Correct identification is only guaranteed for USB I/Os that comply to 100% with the USB
specification.
Table 1-6 Assignment of the USB interface
Type A socket Type B socket Pin Name Type Remark
1 P5V_fused V + 5 V (fused)
2 Data-
B
Data -
3 Data+ Data +
4 GND V Ground (reference potential)
USB sticks
If you want to connect a USB stick to the USB interface, preferably use the tested SIMATIC
USB stick 16 GB for this purpose (Article No.: 6ES7648-0DC60-0AA0). Alternatively, you can
use a USB stick with any memory size. It must, however, meet the following minimum
requirements:
File system: FAT16 or FAT32
Partitioning: only in PC partition format (MBR)
USB sticks that deviate from these requirements have not been tested can may not be
recognized by the NCU.
PROFIBUS DP / MPI interface
Connector type: 9-pin sub-D socket
Max. data transmission rate: 12 Mbit/s
Max. cable length: 100 m