EasyManua.ls Logo

Siemens SINUMERIK 840D sl OP 010 - Installation and Mounting Procedures; Preparation for Panel Mounting

Siemens SINUMERIK 840D sl OP 010
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
5
5.1 Preparation for mounting
Table 5-1 Dimensions of the mounting opening
Width (mm) Height (mm)
450 290
Thanks to the tension jacks on the OP 010, drill-holes or screw holes are not needed.
This retaining method also enables the IP65 degree of protection (but only in conjunction with
a circumferential seal and when the protective USB cap is fitted).
3UHVVXUHSRLQWV
IRUWHQVLRQMDFNV
6HDOLQJDUHD
7HQVLRQMDFNVZLWKVHWVFUHZV
0RXQWLQJSDQHO
,QWKHVHDOLQJDUHD
5]

s
s



Figure 5-1 Dimension sheet for installing the OP 010 operator panel front
Table 5-2 Dimensions to be observed when installing
Mounting depth T3 + clear‐
ance (mm)
Opening depth T5
(mm)
Protrusion P
(mm)
PCU 50.5 104 + 10 380 36
TCU x0.2 53 + 10 353 -15
Operator panel front: OP 010
Manual, 07/2018, A5E36371538B 97