EasyManua.ls Logo

Siemens SINUMERIK 840D sl OP 010 - Settings in the Tcu.ini File

Siemens SINUMERIK 840D sl OP 010
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note
Connecting an MCP via PROFIBUS
If an MCP is connected via PROFIBUS, then the MCP Index = 0 should be set.
Compatibility of software versions
If a "config" file is available for the TCU, the data file structures of older versions are transferred
to the config.ini file and the data file structure is then deleted.
Comment
In the config.ini file comment lines are indicated by the # character preceding a line.
1.4.2.8 Settings in the "TCU.ini" file
Directories
The tcu.ini files is created in the following directories:
NCU: /siemens/system/etc/tcu.ini
/user/system/etc/tcu.ini
/oem/system/etc/tcu.ini
PCU (Windows XP): F:\addon_base\system\etc\tcu.ini
F:\user_base\system\etc\tcu.ini
F:\oem_base\system\etc\tcu.ini
PCU (Windows 7): C:\ProgramData\Siemens\MotionControl\siemens\System
\etc\tcu.ini
C:\ProgramData\Siemens\MotionControl\user\System
\etc\tcu.ini
C:\ProgramData\Siemens\MotionControl\oem\System\etc
\tcu.ini
Note
Only the following entries are evaluated by SINUMERIK Operate:
VNCServer/VetoMode
VNCServer/AlarmBoxTimeOut
VNCServer/FocusTimeout
VNCServer/AdaptResolution
VNCServer/MaxActiveTCUs
VNCViewer/ExternalViewerSecurityPolicy
Structure and content
In the tcu.ini file comment lines are indicated by the # character preceding a line.
General information and networking
1.4 Networking
Operator panel front: OP 010
Manual, 07/2018, A5E36371538B 65