EasyManua.ls Logo

Siemens SINUMERIK 840D sl OP 010 - Page 64

Siemens SINUMERIK 840D sl OP 010
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Range of values Default setting Meaning
SessionNumber = Number
Password = String
SuspendLock = Number 0 or 1 0 0: No displacement disable
1: Displacement disable set
SuspendPriority = Number 1 ... 10 1 1: Lowest priority
10: Highest priority
StartupPrio = Number Boot sequence:
The lower the number the higher
the priority
ScreenOnFocus = String | Number Not relevant
ChannelOnFocus = Number Not relevant
[host_1]
Address = [hostname | IP-Adresse] From data file structure
SessionNumber = NUMBER
Password = STRING
SuspendLock = NUMBER 0 or 1 0 0: No displacement disable
1: Displacement disable set
SuspendPriority = NUMBER 1 ... 10 1 1: Lowest priority
10: Highest priority
StartupActive = 0 0 or 1 Display screen after boot
StartupPrio = NUMBER 0 ... not too high Boot sequence:
The lower the number the higher
the priority
ScreenOnFocus = STRING | NUMBER Not relevant
ChannelOnFocus = NUMBER Not relevant
[host_2]
...
[host_MaxHostIndex]
[T2M2N]
SK1 = ch_grp x 2 x 8 characters Empty Softkey inscription (2 lines)
SK2 = ch_grp x 2 x 8 characters Empty Softkey inscription (2 lines)
SK3 = ch_grp y 2 x 8 characters Empty Softkey inscription (2 lines)
...
SK32 = ch_grp z 2 x 8 characters Empty Softkey inscription (2 lines)
...
General information and networking
1.4 Networking
Operator panel front: OP 010
64 Manual, 07/2018, A5E36371538B

Table of Contents

Related product manuals