EasyManua.ls Logo

Siemens SINUMERIK 840D sl OP 010 - Handling Membrane Connectors

Siemens SINUMERIK 840D sl OP 010
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 digital inputs can be polled by the X70/X205/DTM connector.
Connector designation: X70/X205/DTM
Connector type: 20-pin plug connector
Max. cable length: 0.85 m
Table 1-24 Assignment of connector X70 (MCP, MPP, HAM) / X205 (TCU) / DTM
Pin Name Type Meaning
1 DT1
I
1)
Direct key 1
... ... ...
16 DT16 Direct key 16
17 P5V / CON1
2)
V
+ 5 V input voltage
3)
18 P5V / CON2
2)
+ 5 V input voltage
3)
19 GND Ground
20 GND Ground
1)
The inputs are electrically isolated for MCP / MPP / HAM and DTM.
2)
For the TCU, it is evaluated whether the direct keys have been connected.
3)
Power consumption: 100 mA for MCP / MPP / HAM; 500 mA for DTM
Table 1-25 Signal level
HIGH level: 5 V or open
Low level <= 0.8 V
1.3.2 Handling membrane connectors
When replacing parts it can sometimes be necessary to disconnect membrane connectors
from the boards and reconnect them again.
This should be done as follows:

(1) Clamping frame of socket
Figure 1-8 Removing (left) and attaching (right) a membrane connector
General information and networking
1.3 Connecting
Operator panel front: OP 010
Manual, 07/2018, A5E36371538B 35

Table of Contents