• The computer to be monitored must be congured in the cong.ini conguration le of the
TCU according to the general conguration for a TCU in a separate host section as a
switchover target for this TCU.
Where necessary, a password has to be specied in the conguration, if the VNC server
requires one on the target system (see below).
• To ensure that the TCU recognizes the new switchover target, the TCU requires a restart and
reboot.
• The screen resolution of the observed computer must be adjusted to the characteristics of
the TCU. Otherwise the TCU scales the image it receives to match the display area available
to the TCU, which impairs the quality of the display on the TCU.
Conguration
1&8
7&8
6\VWHPQHWZRUN
1HWZRUN
3*3&
;
;
Figure6-1 Conguration example
Conguration
The cong.ini le is located in the following directory:
NCU:
/user/common/tcu/<TCU name>/common/tcu
PCU/IPC (Windows7 and Windows 10):
C:\ProgramData\Siemens\MotionControl\user\common\tcu\<TCU
name>\common\tcu
The cong.ini le must be stored on the boot server (active DHCP).
Networking
6.3Network conguration
TCU 30.3
Equipment Manual, 03/2023, A5E40874197B AD 57