6.1 Coordinate transformation via frame variables
Job planning
6-2 Programming Manual, 03/2006 Edition, 6FC5398-2BP10-1BA0
Possible frame variable:
Basic frame (basic offset)
Settable frames
Programmable frame
Value assignments and reading the actual values
Frame variable/frame relationship
A coordinate transformation can be activated by assigning the value of a frame to a frame
variable.
Example: $P_PFRAME=CTRANS(X,10)
Frame variable:
$P_PFRAME means: current programmable frame.
Frame:
CTRANS(X,10) means: programmable zero offset of X axis by 10 mm.
<
%.6
;
%.6
<
%16
;
%16
<
(16
;
(16
<
:.6
;
:.6
3B%)5$0(3B8%)5
3B,)5$0(3B8,)5>@
3B3)5$0(
Reading the actual values
The current actual values of the coordinate system can be read out via predefined variables
in the parts program:
$AA_IM[axis]: Read actual value in MCS
$AA_IB[axis]: Read actual value in BCS
$AA_IBN[axis]: Read actual value in BOS
$AA_IEN[axis]: Read actual value in SZS
$AA_IW[axis]: Read actual value in WCS

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals