Parameters
SITRANS F M TRANSMAG 2
Operating Instructions, 11/2009, A5E00102775-07
87
5.2.4 Device ID Clear device identification;
corresponds to HART long address
(device-specific
HART long
address)
1 ... 99 999 (Can only be
set with factory code by
HART)
5.2.5 Manuf. Date Transmitter manufacture date; form:
DDMMYY
(device-specific
manufacture
date)
DDMMYY (Can only be set
with factory code by
HART)
5.2.6 Sensor Input only possible if no data can be read
from SmartPLUG
5.2.6.1 Nom.Diameter
5
Diameter
Inside nominal diameter of the sensor with
probes: interior diameter of the
surrounding tube
(nominal width)
0.1 m
DN2 ... 2000 / 0.5 ... 80 in,
probe
(Only after ’Probe’ is
selected:) 0,1 ... 5 m
5.2.6.2 Product Type
4
Sensor order number (7ME5034
-xxxxx-xxA0)
from SmartPLUG
5.2.6.2 Analog
Transmag
5
Select ’Yes’ for measuring sensors with
an R100 constant
In this case, a CFH value must be entered
in the 6.7.2 menu according to the
following formula:
CFH = 176,715 * DN2/R100,
DN = nominal diameter in mm)
No
No
Yes
5.2.6.3 Serial Number
4
Serial number of sensor (serial number) From SmartPLUG
4)
Parameters apply only to devices with 20 mA/Hart communication and digital output 2 (7ME504x-0xxxx)
5)
Parameters apply only to devices with 20 mA/Hart communication and digital input (7ME504x-2xxxx)
Service
Table A- 6 Function group Service parameters
6.1 Enter Code Input of code number agreed under
"Customer Code" (menu 6.2) for releasing
local parameterization
0 0 ... 9999
(according to setting
under menu 6.2)
6.2 Customer Code Selection of personal code:
Code 0: Parameters are not protected
by a code.
Code >0: Parameters can only be
changed after entering the code under
"Enter Code" (menu 6.1)
0 0 ... 9999
6.3 Service Code Input of factory code for extended service
functions
0 0 ... 99999
6.4 Reset Device reset (without parameter changes) Cancel
Cancel
Reset
6.5 Control Values
6.5.1 Volt. Um
Volt. Uref
Control value for magnetic field current
Control value for reference voltage
6.5.2 Volt. Usig Electrode differential voltage