Siemens Sitrans F Series - Inputs and outputs wizard

Siemens Sitrans F Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
In‐
dex
Parameter Name Data
Type
Access Annotation
20 MODE Un‐
signed8
Read /
write
Batching Mode
0: off, batching disabled
1: 1-stage batching
2: 2-stage batching
3: analog batching
21 INPUT_SELEC‐
TOR
Un‐
signed8
Read /
write
Batch input selection:
0: Mass Flow
1: Volume Flow
4: Standard Volume Flow
5: Fraction Flow Media A
6: Fraction Flow Media B
22 AMOUNT_DONE DS-101 Read only Current amount that is totalized since the start of the batch cycle. Includes
a quality code
23 AMOUNT_RE‐
MAINING
DS-101 Read only Amount that is missing to complete the current batch
24 RECIPE_ID Un‐
signed8
Read /
write
Active recipe that specifies the used parameter set.
Valid range 1…5
25 RECIPE_NAME String16 Read /
write
The recipe´s name
26 RECIPE_TAR‐
GET_AMOUNT
Float32 Read /
write
The recipe´s target amount. Follows the unit setting by RECIPE_TAR‐
GET_AMOUNT
27 REC‐
IPE_AMOUNT_UN
IT
Un‐
sign‐
ed16
Read /
write
Unit code that influences the AMOUNT_DONE, AMOUNT_REMAINING
and RECIPE_TARGET_AMOUNT values
28 - - -
-
29 RECIPE_
FIXED_COMPEN‐
SATION
Float32 Read /
write
Define the fixed pre-stop value. The value is subtracted from 'Amount' to
compensate for application delays in closing the valves.
Analog dosing
30 ANALOG_OUT‐
PUT
DS-101 Read only Calculated set point for analog valve
31 RECIPE_
CUR‐
RENT_CLOSED
Float32 Read /
write
Current level that is used in analog batching mode when the
analog valve shall be closed.
32 RECIPE_
CURRENT_PAR‐
TIAL_OPEN
Float32 Read /
write
Define current level to partly close the analog valve
Communication
2.10 Acyclic communication
FCT030 Profibus (From firmware 4.0)
62 Function Manual, 06/2018, A5E39931906-AB