Standard applications
Table 8-12
Technical data, standard application cables
Coil cable Standard electrode
cable
Basic data No. of conductors 2 3
Min. sqr. area 0.5 mm
2
0.2 mm
2
Shield Yes Yes
Max. capacitance N/A 350 pF/m
Max. cable loop resistance Media temperature:
< 100 °C (212 °F) 40 Ω N/A
> 200 °C (392 °F) 6 Ω N/A
Cable glands on sensor and
transmitter
M20x1.5 gland - Cable ø 5 to 13 mm (0.20 to 0.51 inches)
½ NPT gland - cable ø 5 to 9 mm (0.20 to 0.35 inches)
Special applications, for example low conductivity or electrical noise
Table 8-13
Technical data, special application cables
Coil cable Special electrode cable
Basic data No. of conductors 3 3
Sqr. area 1.5 mm
2
0.25 mm
2
Shield Yes Double
Color code Brown, blue, black Brown, blue, black
Outside color Grey Grey
Ext. diameter 7.8 mm 8.1 mm
Conductor Flexible CU Flexible CU
Isolation material PVC PVC
Ambient temperature Flexible installation -5 to +70°C
(23 to 158°F)
-5 to +70°C
(23 to 158°F)
Non-flexible installtaion -30 to +70°C
(-22 to 158°F)
-30 to +70°C
(-22 to 158°F)
Cable parameter Capacity 161.50 pF/m N/A
Inductance 0.583 μH/m N/A
L/R 43.83 þH/Ω N/A
Technical data
8.8 Cable data
54
www.eltra-trade.com
info@eltra-trade.com
+421 552 601 099