EasyManua.ls Logo

Siemens SITRANS P DS III - Technical Support

Siemens SITRANS P DS III
324 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SITRANS P DS III/P410 (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434626-04, 05/2015
53
Certificates and approvals
HART
PROFIBUS PA and FOUNDATION
Fieldbus
Designation
II 2/3 G Ex nA IIC T4/T5/T6 Gc
II 2/3 G Ex ic IIC T4/T5/T6 Gc
Connection "nA"
U
n
= 45 V
U
m
= 32 V
Connection "ic" To a circuit with the operating values:
U
i
= 45 V
FISCO supply unit
U
O
=17.5 V, I
O
= 570 mA
Linear barrier
U
0
= 32 V, I
0
= 132 mA, P
0
= 1 W
Effective inner capacitance
C
i
= 6 nF
C
i
= 1.1 nF
Effective inner inductance
L
i
= 0.4 mH
L
i
= 7 µH
Explosion protection in accordance
with FM
Certificate of Compliance 3008490
Designation (XP/DIP) or IS; NI; S CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia
IIC T4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III
Permissible ambient temperature T
amb
= T4: -40 ... +85 °C (-40 ... +185 °F)
T
amb
= T5: -40 ... +70 °C (-40 ... +158 °F)
T
amb
= T6: -40 ... +60 °C (-40 ... +140 °F)
Explosion protection as per CSA
Certificate of Compliance 1153651
Designation (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4 ... T6:
CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III
Permissible ambient temperature T
amb
= T4: -40 ... +85 °C (-40 ... +185 °F)
T
amb
= T5: -40 ... +70 °C (-40 ... +158 °F)
T
amb
= T6: -40 ... +60 °C (-40 ... +140 °F)
A
Appendix A
A.1
Certificate
The certificates can be found on the enclosed CD and on the Internet under:
Certificates (http://www.siemens.com/processinstrumentation/certificates)
A.2
Technical support
Technical Support
If this documentation does not provide complete answers to any technical questions you may have, contact Technical
Support at:
Support request (http://www.siemens.com/automation/support-request)
More information about our Technical Support is available at
Technical support (http://www.siemens.com/automation/csi/service)
Internet Service & Support
In addition to our documentation, Siemens provides a comprehensive support solution at:
Service&Support (http://www.siemens.com/automation/service&support) where you will find support news, support
documents including EDDs and software, and also support from experts.

Table of Contents

Other manuals for Siemens SITRANS P DS III