Operating conditions for level
Enclosure -40 … +100 °C (-40 … +212 °F)
Measuring cell with sili‐
cone oil 󹪝lling
-40 … +85 °C (-40 … +185 °F)
Display -20 … +80 °C (-4 … +185 °F)
Storage temperature
-50 … +85 °C (-58 … +185 °F)
Climate class in accordance
with IEC 60721-3-4
4K26
Degree of protection accord‐
ing to IEC/EN 60529/UL50-E
Enclosure with appropriate cable
gland
IP66/Type 4X
IP68 (2 hours at 1.5 m)
Enclosure with mounted M12 device
plug
1)
IP66/Type 4X
Enclosure with external overvoltage
protection up to 6 kV
IP66/Type 4X
Enclosure with mounted HAN device
plug
1)
IP65
Electromagnetic compatibility
Interference emission and
interference immunity
In accordance with EN 61326 and NA‐
MUR NE 21
Process medium conditions
Process temperature
Measuring cell with sili‐
cone oil 󹪝lling
Plus side: See mounting 󹪞ange
Minus side: -40 +100 °C (-40 …
+212 °F)
1)