8.3 Vibration resistance
General operating conditions Gauge pressure series
2)
Aluminum and stainless steel enclo‐
sure
Di󹪜erential pressure series
1)
Aluminum and stainless steel enclo‐
sure
Vibrations (sine)
IEC 60068-2-6
2 ... 9 Hz at 0.3 mm
9 ... 200 Hz at 5 m/s²
1 octave/min
5 cycles/axis
Continuous shocks (half-sine)
IEC 60068-2-27
70 m/s²
30 ms
6 shocks/axis
Continuous shocks (half-sine)
IEC 60068-2-27
250 m/s²
6 ms
1000 shocks/axis
1) Without mounting bracket
2) With mounting bracket
Operating conditions according to
KTA 3503
Gauge pressure series
2)
Aluminum and stainless steel enclo‐
sure
Di󹪜erential pressure series
2)
Aluminum and stainless steel enclo‐
sure
Vibrations (sine)
IEC 60068-2-6
9 ... 35 Hz at 10 m/s²
1 octave/min
1 cycle/axis
Vibrations (sine)
IEC 60068-2-6
5 ... 7 Hz at 20 mm
9 ... 100 Hz at 20 m/s²
10 octave/min
1 cycle/axis
Continuous shocks (half-sine)
IEC 60068-2-27
300 m/s²
11 ms
6 shocks/axis
2) With mounting bracket
Technical data
8.3 Vibration resistance
SITRANS P320/P420