Scale parameters and functions
8.7 DR 6 limit value settings
SIWAREX WP321
64 Manual, 07/2014, A5E33715669A-02
8.7.3
Delay time for limits
If the weight reaches the specified switch value, a delay time (defined in ms) is launched.
Once the delay time is over, the limit switch changes status provided the weight still reaches
the specified switch value.
This delay time applies to the switch-on and switch-off values 1 and 2 and to the switch-on
limit for the empty value. The empty value does not have a switch-off delay.