Scale parameters and functions
8.15 DR 32 Message display
SIWAREX WP321
80 Manual, 07/2014, A5E33715669A-02
5005 Command or data transmission not
possible because service mode is active
BIT r 0 0 1
5006 Command or data transmission not
possible because BUSY
BIT r 0 0 1
5007 Command or data transmission not
possible because module is faulty or
ODIS is active
BIT r 0 0 1
Reserve - BIT r 0 0 1
Reserve - BIT r 0 0 1
5101 Command is not permissible in this
operating state
BIT r 0 0 1
5102 Command not possible because not at
standstill
BIT r 0 0 1
5104 Command not possible because range
is exceeded
BIT r 0 0 1
5105 Load cell parameter not plausible BIT r 0 0 1
Reserve BIT r 0 0 1
5107 Shifting characteristic not possible BIT r 0 0 1
7000 Permitted number range violated BIT 2 r 0 0 1
Reserve - BIT r 0 0 1
Reserve - BIT r 0 0 1
7002 Specifications of string lengths not plau-
sible
BIT r 0 0 1
Reserve - BIT r 0 0 1
Reserve - BIT r 0 0 1
7006 Command only possible in test field BIT r 0 0 1
7007 The calibration weights or calibration
digits are not plausible
BIT r 0 0 1
7008 Zeroing/zero setting or tare parameter
not plausible
BIT r 0 0 1
7009 Standstill range / standstill wait time not
plausible
BIT r 0 0 1
7010 Scale interval / rounding not plausible BIT r 0 0 1
7011 Filter parameter not plausible BIT r 0 0 1
7014 Time input not plausible BIT r 0 0 1
Reserve - BIT r 0 0 1
Reserve - BIT r 0 0 1
7019 RS485 parameter error BIT r 0 0 1
Reserve - USHORT 2 r 0 - -
Reserve - USHORT 2 r 0 - -
Reserve - USHORT 2 r 0 - -