If other data concerning the service life are engraved on the rotor or
bucket, these data shall apply accordingly: For example, a bucket with
the engraving “max cycles = 10,000” has a service life of 10,000 cycles,
and a rotor with the engraving “Exp.Date 02/15” must be scrapped in
Feburary 2015 at the latest (see fig. 5.9)!
Fig. 5.9: Different service life – engraving on the bucket/rotor
Attention!
Refer to the table of rotors and accessories with a different service
life ( see chapter Fehler! Verweisquelle konnte nicht gefunden werden.
“Appendix”)!
5.2.6 Starting the Centrifuge
The centrifuge is ready for operation when the start key is illuminated.
Press the start key in order to start a centrifugation run.
5.2.7 Interrupting a Centrifugation Run
Press the stop key in order to interrupt a centrifugation run.
The centrifugation run will be terminated prematurely.
5.2.7.1 Interrupting a Deceleration Process
Press the start key during a deceleration process in order to interrupt it and to
restart the centrifuge.