Communication via SIKONETZ5
AP04-RS485/SIKONETZ5
Date: 24.11.2016 Art. No. 86218 Mod. status 351/16 Page 38 of 38
8.9.2 Example: Write parameter
Set parameter offset value of node address 1 to value 500:
Write command: 0x01
Node address: 0x01
Parameter address: 0x1E Offset value
Data: 0x00 00 01 F4 ļƒž 500
dec
Telegram from master to slave
1
st
byte
2
nd
byte
3
rd
byte
4
th
byte
5
th
byte
6
th
byte
7
th
byte
8
th
byte
9
th
byte
10
th
byte
Command
Node
address
Parameter
address
CW
Data
Check
sum
0x01
0x01
0x1E
0x00
0x00
0x00
0x00
0x01
0xF4
0xEB
Reply telegram from slave
1
st
byte
2
nd
byte
3
rd
byte
4
th
byte
5
th
byte
6
th
byte
7
th
byte
8
th
byte
9
th
byte
10
th
byte
Command
/ Reply
Node
address
Parameter
address
SW
Data
Check
sum
0x01
0x01
0x1E
0x00
0x01
0x00
0x00
0x01
0xF4
0xEA