Functional Description
AP04-RS485/SIKONETZ5
Date: 24.11.2016 Art. No. 86218 Mod. status 351/16 Page 11 of 38
3.4.1.5 Bus parameters
Menu


Parameter display
Parameter no.
acc. To chapter 4
Description

3
Node address
Value range: 0 - 31

4
Baud rate
Selection:
: 57600 baud
: 115200 baud
: 19200 baud

5
Protocol
Selection:
: SIKONETZ5
: Service protocol

6
Bus Timeout
Value range: 0 - 20

36
Response delay
Value range: 0 - 10
Table 3: Bus parameter menu
3.4.1.6 Positioning
Menu


Parameter display
Parameter no.
acc. To chapter 4
Description

24
Readout per revolution / spindle pitch
Value range: 0 - 59999

15
Decimal places
Selection:
: 0
: 0.1
: 0.02
: 0.003
: 0.0004