Operating manual - English REKORD
Copyright Silca 2 007 27
Lamp protection
ATTENTION:
remove the mains plug
.
1) Remove the two protective pads (Q)
2) Loosen the 3 screws (M1) and remove the top cover (M).
3) Loosen the 2 lamp fixing screws (L1) and remove.
4) Loosen the 2 screws (L2) in order to remove the lamp protection (L3).
5) Fit the new protection and secure with the 2 screws (L2)
6) Replace the lamp unit and secure with the 2 screws (L1) maki ng sure th e wiring is positioned to-
wards the bottom of the machine.
7) Replace the top cover and secure wi
th the 3 screws (M1).
Fig. 37
Fig. 38
8.12 Replacing motor on switch
ATTENTION:
remove the mains plug
.
1) Access the bottom part (see ch. 8.7).
2) Detach the 4 connectors (S2) (fig. 39) paying specia
l attention to their position.
3) Use a screwdriver to turn down the internal switch fixing tabs and pull it out.
4) Fit the new switch in its seat and reconnect the 4 con
nectors (S2) paying special attention to th
eir
position.
5) Replace the bottom grate and secure with the screws (Y) (fig. 28).
6) Place the machine upright on the work bench.
Fig. 39