6.1.3 TECHNICAL FEATURES
Models 30i - 30e SYSTEM
Heat output
Nominal(80-60°C) kW 29,4(NaturalGasat1,13lPa)
29,4(LPGat2,75kPa)
Reduced kW 10,8(NaturalGasat1,13lPa)
11,8(LPGat2,75kPa)
Heat input
Nominal(80-60°C) MJ/h 123,0(NaturalGasat1,13lPa)
123,0(LPGat2,75kPa)
Reduced MJ/h 45,1(NaturalGasat1,13lPa)
49,1(LPGat2,75kPa)
Supply Voltage
V 240(50Hz)
Adsorbed power consumption
W 145
C.H. setting range
°C 20/80
Water content boiler
l 6,1
Maximum water head
bar 3,0
Maximum temperature
°C 85
Capacity of the heating expansion vessel
l 10
Pressure of the heating expansion vessel
bar 1,2
Main burner nozzle
Quantityofinjectors 13
NaturalGas/LPGInjectorDiameter mm 1,45/0,85
NaturalGas/LPGTestPointPressure kPa 0,79/2,50
Weight when empty
kg 31