EasyManua.ls Logo

Sime FORMAT DGT 30e - Technical Features

Sime FORMAT DGT 30e
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
6.1.3 TECHNICAL FEATURES
Models 30i - 30e SYSTEM
Heat output
Nominal(80-60°C) kW 29,4(NaturalGasat1,13lPa)
29,4(LPGat2,75kPa)
Reduced kW 10,8(NaturalGasat1,13lPa)
11,8(LPGat2,75kPa)
Heat input
Nominal(80-60°C) MJ/h 123,0(NaturalGasat1,13lPa)
123,0(LPGat2,75kPa)
Reduced MJ/h 45,1(NaturalGasat1,13lPa)
49,1(LPGat2,75kPa)
Supply Voltage
V 240(50Hz)
Adsorbed power consumption
W 145
C.H. setting range
°C 20/80
Water content boiler
l 6,1
Maximum water head
bar 3,0
Maximum temperature
°C 85
Capacity of the heating expansion vessel
l 10
Pressure of the heating expansion vessel
bar 1,2
Main burner nozzle
Quantityofinjectors 13
NaturalGas/LPGInjectorDiameter mm 1,45/0,85
NaturalGas/LPGTestPointPressure kPa 0,79/2,50
Weight when empty
kg 31
IMPORTANT:
INSTALLATION AND ALL SERVICING MUST BE CARRIED OUT
BY AN AUTHORISED PERSON.

Table of Contents