5.2 REMOvAl OF THE HEATER
In case of need, to remove the heater, it is neces-
sary to discharge pressure.
Then, proceed as follows:
1 Remove machine covers:
• Rearpanel;
• Sidepanels;
• Frontpanel.
2 Empty water heater, as in the previous
section.
3 Disconnect the level probe.
4 Disconnect the pressure gauge capillary.
5 Remove the fittings on the upper part of the
heater with a 17 mm wrench.
A SteamNozzle;
B Coffeedeliverygroup;
C HotWaterNozzle.
6 Remove the remaining fittings that hold the
heater in place.
7 Remove the fittings on the left side:
A usinga17mmwrench;
B using a 12 mm wrench.
The heater can be extracted from the machine.
During the assembly phase of the new boiler, pay
close attention to the restoration of the connec-
tions to ensure proper operation.