EasyManua.ls Logo

Simonelli MUSICA - Yearly Maintenance

Simonelli MUSICA
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ed. 01 of 12/2015
10.3
Service Manual
10.3 YearlY Maintenance
Time required 45 - 60 min:
The skilled technician should take all the necessary precautions concerning safety measures to insu-
late the machine from the mains and to avoid pressure in the heater, waterline closure or tank removal
so as to prevent inconveniences or damages. Before proceeding, remove all machine covers and
check for any damage or leakage.
Before proceeding, remove all perimeter coverings and make sure there are no damages or leakages.
Check for any sign of leakage;
Check all wirings;
Check pump noise;
Check for any drip from the unit, the steam nozzle and the hot water nozzle;
Check non-return valve;
Check self-level function;
Check heater pressure (______Bar);
Check the presence of limescale in the tank;
Check total production of beverages;
Check electrovalve for leakages;
Check heater for leakages;
Replace the group gasket (02280020.C);
Replace shower screen (03000066);
Insert or replace, if necessary, shims under the seal (02060014).
NOTES
The water hardness must be below 6°fr (French degree).
The chlorine content must not exceed 100 mg.
Necessary spare parts:
02280020.C
03000066
02060014