3 Disconnect the hydraulic connections of the
pump:
• From the flowmeter, disconnect the
Teflon pipe “B”.
4 Disconnect the electrical connections of the
pump using the tweezers:
A: temperature probe.
B: power supply.
5 Take the pump out of the machine.
• Fromthe pump to the heater, unscrew
the fitting “C” using a 13 mm spanner.
B
Fig. 79
B
A
Fig. 81
Fig. 80
Flowmeter
Heater
NOTE
NOTE
Check the water inlet filter situated in the
heater connection and replace it, if necessary.
When replacing the pump, replace the O-ring
code No. 02280007.V, too (see tables at the
end of the manual).