Simrad GC80/GC85 Compact Gyro Compass
92 20221511 / D
SWITCH DEFAULT FUNCTION DESCRIPTION
S2-1 OFF
S2-2 OFF
Used for debugging
S2-3 OFF Not used.
S2-4 OFF Pendulum ferry
OFF = Disabled
ON = Enabled
SW2-5 OFF
SW2-6 OFF
= 1sec (1Hz)
SW2-5 OFF
S2-5 OFF
SW2-6 ON
= 100msec (10Hz)
SW2-5 ON
SW2-6 OFF
= 200msec (5Hz)
SW2-5 ON
S2-6 ON
Serial signal transmit
frequency IEC61162-1
ed.2
SW2-6 ON
= Invalid
S2-7 OFF
S2-8 OFF
Not used.
S3-1 OFF Timer startup OFF = No, ON = Yes
S3-2 OFF Talker ID of “ROT”
sentence
OFF = “HE”, ON = “TI”
S3-3 ON
S3-4 OFF
Not used
S3-5 OFF
Ban or permission of a
“ROT” sentence output
Valid at the time of external sensor
(standard) selection.
OFF = Disabled, ON = Enabled
S3-6 ON For Simrad use
OFF = Not used
ON = Simrad GC type (80 or 85) shown in
display at start-up according to S1-2
setting.
S3-7 OFF
S3-8 OFF
Not used