MARIS ECDIS900 Installation Manual
CONNECTING SENSORS
All serial NMEA data is connected to SIS4000-Mk2.
This box has 8 input channels, 2 of them can be set for input/output.
Communication is network based with the ECDIS900 computer over the 2
nd
LAN adapter.
Read more about the installation and configuration in the Annex SIS4000-Mk2
installation and configuration.
Never use RS232! This standard is not galvanic isolated and will ground the entire
24V net on the ship and this may damage connected equipment. RS232 is not allowed
on a SOLAS ship and violates any type approval. Not only does it violate the rule work,
it is also bad engineering and installation practice, which can result in the loss of data
and compromise safety of navigation.
PREPARING THE COMPUTER FOR THE FIRST RUN
All computers must be prepared for their particular installation – installations of two ships
are never alike. Windows 7 US Pro 64 bit is preinstalled and configured according to MARIS
specifications.
Start with the monitoring computer and then go through the others.
FACTORY DEFAULT
All computers leave the factory with these settings.
Windows 7 logon:
Computer name: Monitoring
Workgroup: Maris
User name: Maris
Password: Empty
Network defaults:
Name Type IP-Address Subnet mask Gateway
ECDIS network Work 192.168.3.150 255.255.255.0 Not used
Sensor network Public 192.168.4.200 255.255.255.0 Not used
PcRadar network Public 192.168.5.200 255.255.255.0 Not used