MARIS ECDIS900 Installation Manual
Important notes:
Computer names
The suggested names must be changed to something descriptive, for example,
Monitoring, Planning, Chart Table, Planning 1, MBA or Conning. Always change the
name before software installation.
Workgroup name.
This workgroup name “MARIS” must NEVER be changed.
IP-address.
Addresses in the range 150 to 199 can be freely used.
Subnet numbers when interfacing to old, existing equipment.
This number is marked X in the table and is in the range 1 to 3. Set to 1 on systems
connected to a MARIS VDR2000 or VDR2200 Mk1. Set to 2 on systems not connected
to a MARIS VDR. Set to 3 on systems connected to a MARIS VDR2200 Mk2.
Subnet number on new installations.
Set to 3.
Consilium radars have 2 IP-addresses per radar. In this case, increment the IP-addresses
by 5 instead of 1 to avoid conflicts.
NETWORK BASICS, SENSORS NETWORK
Change settings for TCP/IPv4 as shown in the table.
Other items including TCP/IPv6 are not used and must be left as is.
Computer name Workgroup IP-Address Subnet mask Gateway
Monitoring MARIS 192.168.4.200 255.255.255.0 Not used
This is for use with SIS4000-Mk2 and other network-based sensor modules.
NETWORK BASICS, PCRADAR NETWORK
Change settings for TCP/IPv4 as shown in the table.
Other items including TCP/IPv6 are not used and must be left as is.
Computer name Workgroup IP-Address Subnet mask Gateway
Monitoring MARIS 192.168.5.200
255.255.255.0 Not used