PROGRAMMING SENSOR MONITOR
Create a new sensor. Click Norm Type and select CN8E Router. Click Sensor ID and rename it
to SIS4000. Click Parameters and set up as shown.
Note: Read From/Write To is set to Send & Receive.
PROGRAMMING CHANNELS IN SIS4000
Open the newly created sensor SIS4000. Click More Settings. If the configuration in the
previous chapter is correct, a web interface opens, and from here you can set up the sensors
in the box. At the same time, you can configure the Sensor Monitor.
1. Place a tick mark in channels you want enabled.
2. Click the channel and the line turns blue. Click the column header for the item you
want to change and enter the new value. Pay attention to port numbers.
3. In the web interface, select Channels Settings and change the name to the same
as above.
Note
: The names must be identical, and they are case sensitive. That is, GPS_1 is
not the same as gps_1. Maximum length is 6 characters.
4. Click SAVE when done with all sensors. Then click Ok to close the window.
Channel no. SIS4000 Monitoring SIS4000 Planning1 SIS4000 Planning2
1 8010 8020 8030
2 8011 8021 8031