18
|
Operating the display | MO Series User Manual
Option Sub option Range Description
Conguration Power
Control
Slave,
Master
In slave mode monitor will turn on if 12/24V is
detected on the yellow wire. In master mode
monitor will turn on slave devices by switching 12V
to yellow wire when monitor is on
Key Beeps O, On Turns on or o the OSD key beeps
Factory
Reset
Yes, No Restore all settings to default
Option Sub option Description
Touch Screen HDMI Enables serial touch control for HDMI
DVI Enables serial touch control for DVI
Enable All Enables serial touch control for HDMI and DVI
Disable Disables serial touch control
¼ Note: USB touch control is automatically enabled upon connection.
Updating the rmware
Updates to the MO series monitor rmware may occassionally become available. The updates
will typically include improvements to exisitng functionality or new features, and will be made
available via the Simrad website: www.simrad-yachting.com
Checking current rmware version
On the Conguration page it is possible to see the name of the monitor, resolution (native),
OSD version, BIOS version, and the NMEA 2000 ID.
Installing an Update
Updates should be loaded via a compatible Simrad Multifunction Display or ST10
programming tool. Refer to the applicable product manual on how to upgrade a device over
NMEA 2000.
Alternatively return the device to a Navico dealer to arrange updating.
¼ Note: Upgrading an MO series monitor can only be done one at a time.