SKYJACK, Page 23
April 2006
Component Identification (Special Options) Section 2 - Operation
SJ800 - E Series
Battery Powered
2.3-3 1500W AC Inverter (If Equipped)
The inverter is located on the base of the machine. It has
the following controls:
Figure 2-14. 1500W AC Inverter
Note
The inverter operation is automatic. These
controls do not need to be manipulated
for normal operation.
1.
ON/OFF Switch - This diagnostic slide switch
activates or terminates inverter operation. It should
remain in the “ON” position.
2. Status LEDs - These LEDs indicate the operating
or fault status of the inverter .
3. 15 Amp Circuit Breaker - In the event of a power
overload or circuit grounding, the circuit breaker will
pop out. Push the breaker back in to reset.
4. GFCI Outlet - During inverter operation, this outlet
provides AC power.
4
2
1
3
2.3-4 Motion Alarm (If Equipped)
The alarm produces an audible sound when any con-
trol function is selected. On machines with certain op-