213205AAA SJ82 T, SJ86 T
30
Section 3 – Familiarization Features and devices
FAMILIARIZATION
WARNING
If the platform load sensing system is in the fault mode, the capacity lights ash alternately and the
overload light ashes. The capacity zone border light continuously illuminates as well. Do the steps that
follow:
Make sure the platform is level, and there are no obstructions in contact with the platform.
If the platform load sensing system stays in the fault mode, the emergency-power unit can be used
to lower the platform. Remove the MEWP for servicing. Speak to a qualied service technician for
repairs. If you do not obey, there is a risk of death or serious injury.
3.4-5 Overload status
Weight
Indicator Light Audible Alarm Platform Function Controls
93% - 99% On Off Enabled
100%
(
Work Mode
)
Flashing Pulsing Disabled
100%
(
Travel Mode
)
Flashing Off Enabled
1133AC-CE