8. Maintenance Programme
Repairs that exceed the framework of common maintenance must be
performed only by a qualified expert or the Customer Service Dept. of the
manufacturer. Use only spare parts and accessories approved by the
manufacturer.
Prior to any maintenance or repairs, it is necessary to switch off the
compressor and disconnect it from mains (pull out mains plug).
Before every service intervention it is required to remove the front and back covers,
disconnect the ground connector on the covers.
8.1 Intervals of service
Operation of service Chapter Time interval (hrs)
2000 4000 6000 8000 10 000 12 000
Check of safety valve 1 x per annum
Verification of tightness of
joints and check inspection of
appliance
2000 hours running or after 2 year
Replacement of service kit F
(filters)
X X X X X X
Replacement of service kit A X X X
Replacement of service kit B X X
Replacement of service kit C X