4 How to use
-99-
No.PS※※-OMW0009-A
Product individual parameters
Index
Sub
index
Access
1
Items
Data
type
2
Initial value
Data
storage
3
Set value
Remarks
dec
hex
1000
0X03E8
0
R/W
Display unit
U8
0
Y
0: kPa
1: bAr
2: psi
Setting of display unit
1010
0X03F2
0
R/W
Display colour
U8
2
Y
0: red
1: Grn
2: 1SoG
3: 1Sor
4: 2SoG
5: 2Sor
Setting of display colour
1020
0X03FC
0
R/W
SW output PNP/NPN
selection
U8
1
Y
0: nPn
1: PnP
Setting of switch output
specification
1400
0X0578
0
R/W
OUT2 hardware output
U8
2
Y
0: Distance
1: SUP port
pressure
2: OUT port
pressure
3: Other
1210
0X04BA
1
R/W
Distance
(OUT1)
Output mode
U8
0
Y
0: HYS
1: Wind
Setting of OUT1 output mode
2
R/W
Output style
U8
1
Y
0: Normal output
1: Reverse
output
Setting of OUT1 output normal and
reserved output
1220
0X04C4
1
R/W
HYS mode set value
S16
Refer to
Table "SW
output
default
value".
Y
Refer to
"Distance
measurement
value set
range".
Setting of OUT1 output set value
2
R/W
HYS mode hysteresis
S16
Y
Setting of OUT1 hysteresis
3
R/W
Wind mode lower
limit set value
S16
Y
Setting of OUT1 output set value
(lower limit of window comparator)
4
R/W
Wind mode upper
limit set value
S16
Y
Setting of OUT1 output set value
(upper limit of window comparator)
5
R/W
Wind mode hysteresis
S16
Y
Setting of OUT1 hysteresis
(window comparator hysteresis)
1410
0X0582
1
R/W
Distance
(OUT2)
Output mode
U8
0
Y
0: HYS
1: Wind
Setting of OUT2 output mode
2
R/W
Output style
U8
1
Y
0: Normal output
1: Reverse
output
Setting of OUT2 output normal and
reversed output
1420
0X058C
1
R/W
HYS mode set value
S16
Refer to
Table "SW
output
default
value".
Y
Refer to
"Distance
measurement
value set
range".
Setting of OUT2 output set value
2
R/W
HYS mode hysteresis
S16
Y
Setting of OUT2 hysteresis
3
R/W
Wind mode lower
limit set value
S16
Y
Setting of OUT2 output set value
(lower limit of window comparator)
4
R/W
Wind mode upper
limit set value
S16
Y
Setting of OUT2 output set value
(upper limit of window comparator)
5
R/W
Wind mode hysteresis
S16
Y
Setting of OUT2 hysteresis
(window comparator hysteresis)