‐CW521/531
11
Refertotheconnectiondiagramforthemaximumpermittedheightofwalldrains–(seeTECHNICAL
DATA)
Caution:makesurethattheintakeanddrainhosesarenotbent,constrictedorcrushed
afterinstallation.
When installing the drain hose to a siphon with valve, the maximum height of the drain outlet is
reducedto600mm.
4.2 Electricalconnection
The dishwasher and any additional equipment must be connected to the electrical
system by authorised, skilled staff, in accordance with the relevant regulations; also
complywiththetechnicalinstructionsfortheconnection.
Thetotalratedpowerisstatedontheappliance’stechnicaldataplate.
The electrical protection devices fitted for the dishwasher must serve this appliance
only.
The user must have a master switch and a di fferential safety breaker, with rating
suitable for the appliance’s characteristics, installed on the electricity supply line in
accordancewiththerelevantregulations.
These switches must be installed close to the dishwasher, be easily accessible after
installation, and provide complete disconnection from the electrical mains in
overvoltageclassIIIconditions.
Warning!!!
Thedishwasherisalwayspoweredupunlessthemasterswitchisturnedoff.
Connecttheappliancetotheuser’searthsystem.The
terminalfortheconnectionis
inthebottomright‐handcorneroftheappliance.
The earth wire (PE) is yellow‐greenin colour, the neutralwire (N) is blue and the live
wires(L1,L2,L3)areblack,greyandbrown.
In the event of single‐phase connection (230V‐1N~),
the connection to the electrical
mainsmustbemadeusingacablewithplugcompliantwiththerelevantregulations.
THE POWER SUPPLY CABLE MUST BE REPLACED BY THE MANUFACTURER OR AN
AUTHORISEDSERVICECENTRETOPREVENTALLRISKS.