TOUCHSCREEN CALIBRATION
Select to calibrate or re-calibrate the touch screen. When
prompted, touch the Target and hold until told to release.
The Target will move to four locations on the screen. Touch
and release at each position.
Once all four positions have been selected, the calibration
values are stored and the screen is ready for operation.
TOLERANCES
Tool detection tolerances for the tool silhouettes are pro-
grammed at the factory to achieve an optimum sensitivity
balance. However, some tools may have inconsistent place-
ment in its foam pocket. This inconsistent placement may
cause inconsistent tool detection results. For example, if a
long cord on a power tool is placed in its foam pocket differ-
ently from when the drawer was trained an incorrect tool
warning might be generated. The tool detection tolerances
should be adjusted to minimize these erroneous incorrect
tool warnings.
The administrator has the ability to change the detection tol-
erances for each tool individually. First, nd the tool requir-
ing an adjustment. Tools can be sorted by drawer to ease
the search.
Highlight the “Tool” column for the tool to be adjusted and
click up to increase tolerance thus improving reliability. If
increased sensitivity is desired the tolerance can be de-
creased by clicking the down button.
Select “Done” when adjustment is complete.