9. Press [ENTER]
The display screen will show:
10. Only one machine type at a time will show on
the screen.
Use the [UP & DOWN ARROWS] to select
the correct machine type (the full list is
shown below).
0=MHP
1=SR2770
2=SR3370
3=SR3370eu
4=SR2255
5=SR2755
Death or personal injury and serious
damage to the machine can result from
selecting the incorrect machine type.
ENSURE that the machine type you selected
at the above step is the one you are carrying
out the auto level calibration on.
11. Press [ESC]
The display screen will show:
12. Press the [RIGHT ARROW] to select the
calibrate level function.
The display screen will show:
13. Press [ENTER].
The display screen will show:
14. Press [ESC] to abort the calibration or
[ENTER] to proceed with the calibration
process.
If [ENTER] is selected the display screen
should show:
15. Values should now read approximately 0.0,
0.0. If they do not repeat from step 9.
16. Switch the ignition off and on again.
17. Check that the machine now levels correctly.
SR3370 & SR2770 – 13184B Rev D page 21
Maintenance Information
CALIBRATE LEVEL:
YES:ENTER.NO:ESC
CALIBRATE LEVEL:
TILT 0.0’.0.O’
MACHINE SETUP:
CHANGE DEFAULTS
DEFAULTS:
1=SR2770
DANGER
MACHINE SETUP:
CHANGE DEFAULTS
MACHINE SETUP:
CALIBRATE LEVEL