Page 2 - 24 UL25/UL32/UL40
INSPECTION AND MAINTENANCE
Table 2-2: Daily preventative maintenance
checklist
DAILY PREVENTATIVE MAINTENANCE SCHEDULE
MAINTENANCE TABLE KEY PREVENTATIVE MAINTENANCE REPORT
Y = Yes/Acceptable Date: ______________________________
N = No/Not Acceptable Owner: _____________________________
R = Repaired/Acceptable Model #: ____________________________
Serial #: ____________________________
Serviced by: _________________________
Operator’s
Manual
Check that the operators manual is in
the manual holder and all pages are
intact and readable
Labels &
Decals
Check that labels and decals are in
place, intact and readable
Control
Cable
Check the exterior of the cable for
pinching, binding or wear.
Mast
Assembly
Inspect for bends, cracks or loose
rivets.
Battery
System
Check electrolyte level
Check battery cable condition
Check terminals are clean and connec-
tors are tight
Check charger condition and operation
Charge batteries
Hydraulic
uid
Check oil level
Hydraulic
system
Check all ttings are tight and there are
no leaks
Drive motors Check for operation and leaks
Hydraulic
pump
Check ttings are secure and there are
no leaks
Emergency
lowering
Operate the emergency lowering valve
and check for serviceability.
Controller Check switch operation
Platform
deck and
rails
Check fasteners are in place, correctly
tightened and not damaged
Check the structure and welds for dam-
age, deformation, corrosion and cracks
Check condition of deck (no damage,
deformation, corrosion or cracks
Check entry gate closure functions
correcly
Elevating
assembly
Inspect for external damage, dents, loose
rivets or cracks.
Check the structure and welds for dam-
age, deformation, corrosion and cracks
Chassis Check operation of outrigger interlocks
Check castors for damage
Check hoses for pinch or rubbing points
Check welds for cracks
Lift Cylinders Check for leaks
Harness
anchor point
Check fasteners are secure
Check for damage, deformation, corrosion
and cracks
System func-
tion inspec-
tion
Conduct system function inspection (see
system function inspection pocedure)
Emergency
stops
Check that the emergency stop button on
the basket panels opertates correctly
Check that the emergency stop button
on the ground control panel operates
correctly
Alarm Check that the alarm sounds when
activated
* NOTE: Use ISO #46 during summer
and ISO #32 during winter
COMPONENT
INSPECTION OR SERVICES
Y N
R
COMPONENT
INSPECTION OR SERVICES
Y
N
R