SOFAR 1.1K~3KTL User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
setting is forbidden, it can only be set after LCD setting. Key in passwords for
country setting through LCD (default: 0001), country setting can be set in 24h after
keying in the correct passwords, over 24h, set through LCD again.
Set the total power generation. You can modify the total power generation
through this option.
Set the address (when you need to monitor multiple inverters simultaneously),
Default 01.
Set the inverter display language.
14. Insulation Resistance
User can modify the above 4 parameters of the machine through the SD card,
and the user needs to copy the parameter information that needs to be modified into
the SD card in advance.
Note:To enable this feature, please contact the Sofarsolar technical support .
Dry contact test, only suitable for models with dry contacts.
Enable or disable reactive functions.
Enable or disable the power derate function of the inverter, and set the derate
ratio.
Enable or disable the anti-reflux function of the inverter, and set the reflux
power.This function need to be used with external CT, please refer to this manual