Main Inverter Status
Status
Inverter
SN 07318000C
Power
7.6 kW
Voltage
240Vac
Frequency
60 Hz
P_OK: 15 of 30
Optimizers
Connected
Server Comm.
S_OK
(LAN)
Status
Production
Switch
OFF
CosPhi
1.00
Limit
No Limit
Country
USA2
Voltage
380 Vdc
Temp
156 F
Fan
OK
Switch Off. Production disabled›
Commissioning›
Inverter: The inverter serial number
Power: The AC output power
Voltage (Vac): The AC output voltage
Frequency: The AC output frequency
P_OK: xxx of yyy: There is a connection to the power optimizers and at least one
power optimizer is sending monitoring data. XXX is the number of power optimizers
for which telemetries have been received in the last two hours. YYY is the number
of paired power optimizers identified during the most recent pairing process. If XXX
and YYY are not equal, there may be a problem in one or more power optimizers.
S_OK:The connection to the monitoring platform. (Server Connected appears only
if the inverter is connected to the monitoring platform).
Chapter 4: Activating, Commissioning and Configuring the System 49
EV Charging Single Phase Inverter Guide MAN-01-00588-1.1