Figure 9: Power optimizers connected in series
3.
If you intend to monitor the installation, using the monitoring platform, record the
physical location of each power optimizer, as described in
Creating Logical and
Physical Layout using Installation Information
on page 56.
Step 4: Verifying Proper Power Optimizer Connection
When a module is connected to a power optimizer, the power optimizer outputs a safe
voltage of 1V (±0.1V). Therefore, the total string voltage should equal 1V times the
number of power optimizers connected in series in the string. For example, if 10 power
optimizers are connected in a string, then 10V should be produced.
Make sure the PVmodules are exposed to sunlight during this process. The power
optimizer will only turn ON if the PVmodule provides at least 2W.
In SolarEdge systems, due to the introduction of poweroptimizers between the PV
modules and the inverter, the short circuit current I
SC
and the open circuit voltage V
OC
hold different meanings from those in traditional systems.
For more information about the SolarEdge systems string voltage and
current, refer to the
V
OC
and I
SC
in SolarEdge Systems Technical Note
,
available on the SolarEdge website at:
https://www.solaredge.com/sites/default/files/isc_and_voc_in_solaredge_
sytems_technical_note.pdf .
To verify proper power optimizer connection:
Measure the voltage of each string individually before connecting it to the other strings
or to the inverter. Verify correct polarity by measuring the string polarity with a
voltmeter. Use a voltmeter with at least 0.1V measurement accuracy.
NOTE
Since the inverter is not yet operating, you may measure the string voltage and
verify correct polarity on the DC wires inside the Connection Unit with Safety
Switch.
EV Charging Single Phase Inverter Guide MAN-01-00588-1.1
28 Step 4: Verifying Proper Power Optimizer Connection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge EV Series and is the answer not in the manual?

SolarEdge EV Series Specifications

General IconGeneral
AC Frequency60 Hz
Protection RatingIP65
AC Voltage208/240 V
EV Charger Output Voltage208/240 V
EV Charger Max. Output Current32 A
CommunicationEthernet, Wi-Fi
SafetyUL1741
Operating Temperature Range-25°C to 60°C

Related product manuals