Connecting a Single Battery Module
If you are installing a single battery module, connect it to the inverter as follows:
1.
Make sure the battery module's DCswitch is off.
2.
Before connecting the cables between the towers and the inverter, make sure the
accessory kit is of the correct length (see below).
CAUTION!
Note the following cable parameters, it is extremely important for durable
installation as the current flowing through the cables may exceed 100A.
PN Type Cable length
DC
Ground
Communication
IAC-RBAT-5KCINV-01 (to
Hub Inverter)
IAC-RBAT-5KCINV-02 (to
Wave Inverter)
Battery
Pack To
Inverter
57 55 57
IAC-RBAT-5KCTOW-01
Tower to
Tower
260 170 170
IAC-RBAT-5KCBAT-01
Module
to
Module
(Same
Tower)
260 260 260
If you need a longer cable, you will have to crimp the connectors yourself using one
of the following kits: