SolarMax MT-Serie
8MT2 / 10MT2 / 13MT2 / 13MT3 / 15MT2 / 15MT3
Gerätedokumentation n Instruction manual n Documentation d’appareil
n Documentación del dispositivo n Documentazione dell’apparecchio

Table of Contents

Other manuals for SolarMax 10MT2

Questions and Answers

  • S
    Sharon JohnsonSep 3, 2025
    What does 'RTC error' mean on SolarMax 10MT2 Inverter?
    • D
      Douglas MelendezSep 3, 2025
      The 'RTC error' on your SolarMax Inverter indicates that the real-time clock in the inverter is malfunctioning, and the date and time have been reset. If this problem happens frequently, contact the SolarMax Service Centre. Set the time and date correctly.
  • L
    Lisa DavisSep 2, 2025
    What to do if SolarMax Inverter displays 'Program Firmware'?
    • V
      Virginia LopezSep 3, 2025
      If your SolarMax Inverter displays 'Program Firmware', it means the inverter firmware is currently being updated. The inverter automatically resumes mains operation once the firmware update is complete.
  • J
    Julie PierceSep 1, 2025
    What causes 'External blocking' on SolarMax 10MT2?
    • L
      Lisa HarrisSep 2, 2025
      The 'External blocking' message on your SolarMax Inverter indicates a 0% command from MaxRemote, which is coming from the grid operator. You must wait until the grid operator suspends the blocking of the inverter via MaxRemote.
  • J
    Jack SantosAug 31, 2025
    What does 'Error DC polarity' mean on SolarMax 10MT2 Inverter?
    • N
      ngilesSep 1, 2025
      If your SolarMax Inverter displays 'Error DC polarity', it indicates that one or more DC connections are connected incorrectly. Correct this by ensuring that you connect the DC supplies correctly.
  • K
    Kyle LambAug 30, 2025
    What causes 'Temperature limitation' on SolarMax 10MT2 Inverter?
    • F
      floresjosephAug 31, 2025
      The 'Temperature limitation' message on your SolarMax Inverter indicates that the feed-in power has been temporarily reduced to limit the temperature of the inverter. To resolve this, clean the fan grids and improve ventilation in the operations room.
  • S
    sotojennaAug 30, 2025
    What does it mean if L and N are interchanged on SolarMax 10MT2?
    • J
      Julie ValenzuelaAug 30, 2025
      If your SolarMax Inverter indicates that 'L and N' are interchanged, it means a phase and the neutral conductor are incorrectly connected. To fix this, connect the AC supplies correctly.
  • G
    Gilbert LuceroAug 29, 2025
    What does 'Burst error' mean on SolarMax 10MT2?
    • H
      Haley BraunAug 29, 2025
      A 'Burst error' on your SolarMax Inverter means that the inverter disconnected from the grid five times or more on the same day. This warning is displayed for the remainder of the day, and the error counter will reset when the system restarts in the morning. Check your plant’s status logger in MaxWeb xp (if present) or check the grid parameters. If this happens repeatedly, contact our SolarMax Service Centre.
  • Q
    qschroederAug 28, 2025
    What to do if SolarMax 10MT2 displays 'Vac 10min too high'?
    • A
      angela86Aug 28, 2025
      If your SolarMax Inverter shows a 'Vac 10min too high' error, it means the maximum 10-minute average value of the mains voltage at the specified phase is too high. If this problem continues to occur, contact the responsible grid operator.
  • J
    Julie ChambersAug 27, 2025
    What to do if SolarMax 10MT2 shows 'Mains error'?
    • Y
      yangkristinAug 27, 2025
      If your SolarMax Inverter is displaying a 'Mains error', this indicates that the grid has been switched off. If this problem continues to occur, contact the responsible grid operator.
  • A
    Andrea LynchAug 26, 2025
    What does 'Insulation fault DC' mean on my SolarMax 10MT2?
    • J
      Jeffrey PittsAug 27, 2025
      The 'Insulation fault DC' error on your SolarMax Inverter indicates that the insulation resistance of the PV generator against earth is too low. In this case, you should check the PV generator.

Summary

About this Instruction Manual

Target Audience and Manual Handling

Identifies the manual's intended users and provides guidance on its storage.

Symbols and Indicators Explained

Explains various symbols used in the manual and on the inverter for clarity.

Safety Instructions

Appropriate Use and Safety Guidelines

Specifies correct usage and essential safety precautions for the inverter.

Product Description

Block Circuit Diagram

Illustrates the internal functional components and connections of the inverter.

External Features and Dimensions

Details the physical layout, dimensions, and external components of the inverter.

Installation Guide

Transport, Storage, and Siting

Covers essential aspects of handling, storing, and selecting an installation location.

Lightning Protection

Addresses requirements for protecting the PV plant from lightning strikes.

Scope of Delivery and Mounting

Lists included items and provides instructions for physically mounting the inverter.

Electrical Connection Overview

Introduces the various electrical connection points and options for the inverter.

Integrated Overvoltage Protection

Explains the built-in surge protection mechanisms on DC and AC sides.

AC Connection Procedure

Details the process for connecting the inverter to the AC grid.

DC Connection Procedure

Outlines the steps for connecting the PV generator's DC output.

Status Signalling and Monitoring

Covers status signalling contacts and external input monitoring functions.

Communication and Grounding

Details communication sockets and external protective conductor requirements.

Earth Leakage Circuit Breaker

Discusses the integrated leakage current sensor and ELCB selection.

Commissioning Procedures

Powering On and Off

Provides instructions for safely switching the inverter on and off.

Initial Setup Process

Guides through the first-time setup and configuration of the inverter.

Inverter Operation

Graphics Display and Navigation

Explains how to use the inverter's front panel display, buttons, and menu system.

Menu Structure and Key Data

Provides an overview of the menu hierarchy and access to main operational data.

Measured Values and Statistics

Details how to access current measurements and historical operating statistics.

Configuration and System Settings

Covers setting parameters for advanced functions and system configurations.

Automated Testing

Starting and Performing Auto Test

Explains how to initiate and conduct the automated system test.

Data Communication Options

Configuring Communication Interfaces

Details the settings for RS485 and Ethernet interfaces for data exchange.

Accessory Components

Operating Status Indicators

Status Messages and LEDs

Explains the meaning of status messages and LED indicators for device status.

Booting, Mains Operation, and Comms

Covers status information related to startup, grid operation, and communication activity.

Troubleshooting Guide

Service Centre Contact Information

Provides contact details for technical support and service inquiries.

Diagnosis and Remediation Measures

Offers systematic steps to diagnose and resolve common issues, warnings, and errors.

Maintenance and Disposal

Regular Maintenance and Disposal Guidelines

Outlines simple maintenance tasks and procedures for environmentally sound product disposal.

Technical Specifications

Input;Output Values and Efficiency

Lists key electrical parameters, input/output ratings, and efficiency metrics.

Temperature Derating Effects

Illustrates how ambient temperature affects output power for different models.

Individual Country Settings

Details parameter variations required for different countries and grid codes.

Product Guarantee and Warranty

Guarantee Terms and Conditions

Explains the duration and conditions of the product guarantee.

Limitations and Exclusions

Outlines cases where the guarantee does not apply.

EC Declaration of Conformity

Compliance with EMC and LV Directives

Confirms adherence to Electromagnetic Compatibility and Low Voltage Directives.

Product Standard Compliance

Lists specific harmonized standards the products meet for safety and performance.

SolarMax 10MT2 Specifications

General IconGeneral
BrandSolarMax
Model10MT2
CategoryInverter
LanguageEnglish

Related product manuals