When two or more DRM
modes work at the same
time, take the optimal result
that can satisfy both of them.
The active power of the inverter output power
starts to recover.
Description: The inverter outputs according to
the active power percentage set by DataHub.
5.3.3 Other Setting
Meter Reversion: When the current direction of the user's meter is reversed, there is no need to rewire, just turn on
the enable switch and submit this setting.
Main Breaker Limit: Valid only when the EV charger is available. By controlling the charging power of EV
charger, limit the current taken from the grid no more than the set value.
Maximum Unbalance Power: Valid only when the EV charger is available. By controlling the charging power of
EV charger, limit the power differences between each phase no more than the set value.
Plc enabled: Used with plc box of our company. If the plc box is used, turn on the “enable” switch and submit; If
the plc box is not used, Datahub will not found equipment even the “Enable” switch is turned on.