EasyManua.ls Logo

SolaX Power DataHub 1000 - 5.4.4 IV Curve Scanning; 5.5 Smart Scene

SolaX Power DataHub 1000
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DataHub 1000 User Manual
16
Mode
Operate
Explanation
Note
DRM1
Close S9,S1,
disconnect S0
Close S1charging power is 0%
When two or more DRM
modes work at the same
time, take the optimal result
that can satisfy both of them.
DRM5
Close S9,S5
Inverter does not output active power
DRM6
Close S9,S6
The active power output by the inverter does
not exceed 50% of the rated power
DRM7
Close S9,S7
The active power output by the inverter does
not exceed 75% of the rated power
DRM8
Close S9,S8
The active power of the inverter output power
starts to recover.
Description: The inverter outputs according to
the active power percentage set by DataHub.
5.3.3 Other Setting
Meter Reversion: When the current direction of the user's meter is reversed, there is no need to rewire, just turn on
the enable switch and submit this setting.
Main Breaker Limit: Valid only when the EV charger is available. By controlling the charging power of EV
charger, limit the current taken from the grid no more than the set value.
Maximum Unbalance Power: Valid only when the EV charger is available. By controlling the charging power of
EV charger, limit the power differences between each phase no more than the set value.
Plc enabled: Used with plc box of our company. If the plc box is used, turn on the “enableswitch and submit; If
the plc box is not used, Datahub will not found equipment even the “Enableswitch is turned on.

Related product manuals