DataHub 1000 User Manual
18
5.4.2 Remote System Switch
Remote control of inverter switching. (Can be operated in batches)
5.4.3 Parameter Setting
Professionals can read and write the inverter through the inverter's “Modbus Opcode”, under which there are
“READ_HOLDING_REGISTERS”, “READ_INPUT_REGISTERS”,
“WRITE_SINGLE_REGISTER”and“WRITE_MULTIPLE_REGISTERS”. (Can be operated in batches)
5.4.4 IV Curve Scanning
This function can collect the corresponding PV power of different PV voltage in each PV.
i) Click the icon in the operation content, and the IV curve scanning interface will pop up.
ii) Select “Start scanningand wait for a while until the IV curve displays. The user can also export the curve by
clicking “Export”.
*Note: The “IV Curveis exclusive for X1-BOOST-G4 and X1-MINI-G4.