Setting Setting
66
67
Ø
System Switch
System Switch can be chosen from ON or OFF.
ON means the inverter is on working condition and it is inverter default
status..
OFF means the inverter stop delivering all power, but the LCD remains on.
>Switch
>ON<
System Switch
Ø
About
This interface shows information of the inverter including inverter serial
number, Register1 serial number, Register2 serial number, inverter type,
master DSP1,manager and internal code and so on.
Inverter SN
Register1 SN
Register2 SN
About
About
Inverter SN
Register1 SN
Inverter Type
Inverter DSP1
Manager ARM
Internal Code
SystemRunTime
Register2 SN
Register1 SN: it indicates the serial number of the
external monitoring devices,such as pocket WiFi,
pocket LAN and pocket GPRS.
Register2 SN: it indicates the serial number of built
-in Ethernet.
f-3-5) Reset Mgr EE
User can reset the inverter manager parameter records here.
Reset Load 1
>No<
Reset Load
f-3-6) Config guide
This interface will trigger the initial setting guide re-play again.
>Start
Config guide
f-4) CT/Meter Setting
X1-Hybrid need to work with an energy meter or a CT to achieve hybrid
functions. To choose meter or CT used is according to user’s wishes. If meter is
chosen, user also can turn off meter function so that X1-hybrid inverter can work
as normal grid-tied inverter without meter connected.
In hybrid system, it can install two meters to monitor both solax inverter and
other power device. These two meters need to be set different addresses.
Address 001 and address 002 are default and will be written to meters in factory.
And user do not need to change the address except specific situation.
f-5) New Password
User can set the new password here.
Meter
CT/Meter Setting
>Select
Enable
CT/Meter Setting
>Meter function
001
CT/Meter Setting
>Meter1 Addr

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solax X1-Hybrid Series and is the answer not in the manual?

Solax X1-Hybrid Series Specifications

General IconGeneral
TypeHybrid Inverter
Number of MPPTs2
Protection RatingIP65
Frequency Range50Hz/60Hz
Cooling MethodNatural Convection
ModelX1-Hybrid Series
Battery Voltage Range40 V - 60 V
Max Charging Power3.0 kW
Max Discharging Power3.0 kW
CommunicationWiFi
Operating Temperature Range-25°C ~ +60°C