Setting Setting
66
67
Ø
System Switch
●”System Switch” can be chosen from “ON” or “OFF”.
“ON” means the inverter is on working condition and it is inverter default
status..
“OFF” means the inverter stop delivering all power, but the LCD remains on.
>Switch
>ON<
System Switch
Ø
About
●This interface shows information of the inverter including inverter serial
number, Register1 serial number, Register2 serial number, inverter type,
master DSP1,manager and internal code and so on.
Inverter SN
Register1 SN
Register2 SN
About
About
Inverter SN
Register1 SN
Inverter Type
Inverter DSP1
Manager ARM
Internal Code
SystemRunTime
Register2 SN
Register1 SN: it indicates the serial number of the
external monitoring devices,such as pocket WiFi,
pocket LAN and pocket GPRS.
Register2 SN: it indicates the serial number of built
-in Ethernet.
f-3-5) Reset Mgr EE
User can reset the inverter manager parameter records here.
Reset Load 1
>No<
Reset Load
f-3-6) Config guide
This interface will trigger the initial setting guide re-play again.
>Start
Config guide
f-4) CT/Meter Setting
X1-Hybrid need to work with an energy meter or a CT to achieve hybrid
functions. To choose meter or CT used is according to user’s wishes. If meter is
chosen, user also can turn off meter function so that X1-hybrid inverter can work
as normal grid-tied inverter without meter connected.
In hybrid system, it can install two meters to monitor both solax inverter and
other power device. These two meters need to be set different addresses.
Address 001 and address 002 are default and will be written to meters in factory.
And user do not need to change the address except specific situation.
f-5) New Password
User can set the new password here.
Meter
CT/Meter Setting
>Select
Enable
CT/Meter Setting
>Meter function
001
CT/Meter Setting
>Meter1 Addr