4. Technical Data
4.1 DC input ( apply to version E, I, C )
4.2 AC output/input ( apply to version E, I, C )
Max. recommended DC power [W]
Max. DC voltage[V]
Norminal DC operating voltage[V]
MPPT voltage range [V]
MPPT voltage range@full load [V]
Max. input current [A]
Max. short circuit current [A]
Start input voltage [V]
Start output voltage [V]
No. of MPP trackers
Strings per MPP tracker
Backfeed current to PV array
DC disconnection swtich
4000
600
360
125-550
160-500
10/10
14/14
85
150
2
1
0
X1-Hybrid-3.0-D
Model
A
B
C
D
E F
G
I J AKA L M
EPS
Grid
+
PV1 PV2 BAT
+ +
- - -
ON
OFF
WiFi
Upgrade
DRM/Meter
COM
BMS
CAN/GEN
H
X1-Hybrid-3.0-N
X1-Hybrid-3.7-D
X1-Hybrid-3.7-N
X1-Hybrid-4.6-D
X1-Hybrid-4.6-N
X1-Hybrid-5.0-D
X1-Hybrid-5.0-N
5000
600
360
125-550
195-500
10/10
14/14
85
150
2
1
0
6000
600
360
125-550
240-500
10/10
14/14
85
150
2
1
0
6000
600
360
125-550
260-500
10/10
14/14
85
150
2
1
0
Norminal AC power[VA]
Max. apparent AC power[VA]
Rated grid voltage(range)[V ]
Rated grid frequency[Hz]
Norminal AC current[A]
Max.AC current[A]
Displacement power factor
Total harmonic distortion(THDi)
Load control
3000
3000
13
14.4
X1-Hybrid-3.0-D
Model
X1-Hybrid-3.0-N
X1-Hybrid-3.7-D
X1-Hybrid-3.7-N
X1-Hybrid-4.6-D
X1-Hybrid-4.6-N
X1-Hybrid-5.0-D
X1-Hybrid-5.0-N
3680
3680
16
16
4600
4600
20
21
4999
4999
21.7
21.7
AC output
220/230/240 (180 to 270)
50/60
0.8 leading...0.8 lagging
< 2%
optional
AC input
3000
13
14.4
13+17.4(bypass)
14.4+21.7(bypass)
3680
16
16
16+17.4(bypass)
16+21.7(bypass)
4600
20
21
20+17.4(bypass)
21+26.0(bypass)
4999
21.7
21.7
21.7+17.4(bypass)
21.7+26.0(bypass)
220/230/240 (180 to 270)
50/60
0.8 leading...0.8 lagging
Introduction Technical Data
14
15
Qualified electrician will be required for the installation.
WARNING !
3.4 Terminals of PV inverter
3000+4000(bypass) 3680+4000(bypass) 4600+5000(bypass) 4999+5000(bypass)
optional
Norminal AC power[VA](E&C Version)
Norminal AC power[VA](I Version)
Rated grid voltage(range)[V ]
Rated grid frequency[Hz]
Norminal AC current[A](E&C Version)
Max.AC current[A](E&C Version)
Norminal AC current[A](I Version)
Max. AC current[A](I Version)
Displacement power factor
AC inrush current
AC maximum output fault current
35 35 35 35
80 80 80 80
Object
A
B
C
D
E
F
G
H
I
J
K
L
M
DC switch (optional)
PV connection area
Battery connection area
EPS output
Grid output
WiFi port for external Pocket WiFi
Waterproof valve
Earthing screw
CAN communication port for parallel operation/
Generator communication port
(Both functions are being developed.)
Ethernet port
DRM port / External meter port
USB port for upgrading
Description
Battery communication